Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Neurosci ; 58(9): 4070-4083, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37787445

RESUMO

Parkinson's disease (PD) research on specific neuroimaging and neurophysiological biomarkers revealing executive dysfunction mechanisms is limited, necessitating validation. Thus, our study aimed to assess associations between electroencephalographic power spectral density (PSD-EEG), striatal [18 F]Fluorodopa uptake and neuropsychological executive function (EF) testing parameters in PD, while also estimating their diagnostic accuracy. We compared resting PSD-EEG, striatal [18 F]Fluorodopa uptake ratios based on positron emission computed tomography ([18 F]FDOPA PET/CT) and neuropsychological EF tests outcomes [Trail Making Test (TMT) and Stroop Test (ST)] between PD patients and healthy controls (HCO) and then calculated correlations among these measures separately for each group. Additionally, we estimated PD diagnostic accuracy of the PSD-EEG and [18 F]FDOPA PET/CT parameters. In PD patients, we observed the following: (i) slower EEG waves, reflected in increased power of the EEG theta and lower-alpha bands in frontal lobe areas; (ii) reduced [18 F]FDOPA PET/CT uptake in the putaminal and caudate nuclei, along with a decreased putamen-to-caudate ratio ([18 F]FDOPA PET/CT PCR); and (iii) longer performance times evident in nearly all EF tests' parameters. Slower EEG waves correlated negatively with [18 F]FDOPA PET/CT PCR and positively with most of the EF test parameters. Furthermore, we found negative correlations between [18 F]FDOPA PET/CT PCR and certain EF measures related to ST. [18 F]FDOPA PET/CT ratios and several PSD-EEG parameters, particularly those from the prefrontal cortex, demonstrated clinically reasonable diagnostic accuracy for PD. In conclusion, EEG waves slowing in the frontal lobe were correlated with striatal dopaminergic deficiency and impaired executive function in mild PD patients and showed promise as a biomarker of PD-related executive dysfunction.


Assuntos
Doença de Parkinson , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Di-Hidroxifenilalanina , Corpo Estriado , Tomografia por Emissão de Pósitrons/métodos
2.
Appl Bionics Biomech ; 2023: 1135733, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304836

RESUMO

The study aimed to compare the technique of normal gait with the Nordic walking (NW) gait with classical and mechatronic poles in patients with ischemic heart disease. It was assumed that equipping classical NW poles with sensors enabling biomechanical gait analysis would not cause a change in the gait pattern. The study involved 12 men suffering from ischemic heart disease (age: 66.2 ± 5.2 years, body height: 173.8 ± 6.74 cm; body mass: 87.3 ± 10.89 kg; disease duration: 12.2 ± 7.5 years). The MyoMOTION 3D inertial motion capture system (Noraxon Inc., Scottsdale, AZ, USA) was used to collect biomechanical variables of gait (spatiotemporal and kinematic parameters). The subject's task was to cover the 100 m distance with three types of gait-walking without poles (normal gait), walking with classical poles to NW, and walking with mechatronic poles from the so-called preferred velocity. Parameters were measured on the right and left sides of the body. The data were analyzed using two-way repeated measures analysis of variance with the between-subject factor "body side." Friedman's test was used when necessary. For most kinematic parameters, with the exception of knee flexion-extension (p = 0.474) and shoulder flexion-extension (p = 0.094), significant differences were found between normal and walking with poles for both the left and right side of the body and no differences due to the type of pole. Differences between the left and right movement ranges were identified only for the ankle inversion-eversion parameter (gait without poles p = 0.047; gait with classical poles p = 0.013). In the case of spatiotemporal parameters, a reduction in the cadence step value using mechatronic poles and the stance phase using classical poles compared to normal walking was observed. There was also an increase in the values for step length and step time regardless of the type of poles, stride length, and swing phase when using classical poles and stride time when using mechatronic poles. The differences between the right and left sides of the measurement occurred when walking with both types of poles for single support (gait with classical poles p = 0.003; gait with mechatronic poles p = 0.030), stance phase (gait with classical poles p = 0.028; gait with mechatronic poles p = 0.017) and swing phase (gait with classical poles p = 0.028; gait with mechatronic poles p = 0.017). Mechatronic poles can be used in the study of the biomechanics of gait in real-time with feedback on its regularity because no statistically significant differences were found between the NW gait with classical and mechatronic poles in the studied men with ischemic heart disease.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36612484

RESUMO

This study compared selected temporal and kinematic parameters of normal gait and Nordic Walking (NW) performed with classic and mechatronic poles (classic poles equipped with sensors). It was assumed that equipping NW poles with sensors for biomechanical gait analysis would not impair the NW walking technique. Six professional NW instructors and athletes, including three women, participated in the study. The MyoMotion MR3 motion analysis system was used to collect gait kinematic variables. The subject's task was to cover a 100-m distance with three types of gait: a gait without poles, a gait with classic NW poles, and a gait with mechatronic poles at the preferred speed. Parameters were measured both on the right and left sides of the body. No significant differences were found between gait types for three temporal parameters: step cadence, step, and stride time. For the other variables, all the differences identified were between free-walking and walking with poles, with no differences between standard and mechatronic poles. For nine kinematic parameters, differences between free-walking and walking with poles for both the left and right sides were found, while no differences were due to the pole type. All temporal parameters were characterized by symmetry, while among kinematic parameters, only two were asymmetrical (shoulder abduction-adduction in walking with regular poles and elbow flexion-extension in walking without poles). Equipping classic NW poles with additional signaling and measuring devices (mechatronic poles) does not impair the NW technique, making it possible to use them in further studies of gait biomechanics.


Assuntos
Marcha , Caminhada , Humanos , Feminino , Movimento , Caminhada Nórdica , Análise da Marcha
4.
J Am Soc Mass Spectrom ; 29(10): 1941-1950, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29951841

RESUMO

Recently, dozens of new psychoactive substances have appeared on the European drug market every year. The most abundant group of these compounds is synthetic cannabinoids. In the first few years of the "legal highs" phenomenon, JWH (John W. Huffman) compounds were especially popular among drug users. However, the group of synthetic cannabinoids is constantly expanding, as new compounds are created by replacing known structural elements with different chemical groups. The problem with the identification of novel substances in forensic laboratories results from the structural similarity of the compounds and the rapid introduction of newer designer drugs on the black market. In this study, the fragmentation patterns of 29 new-type synthetic cannabinoids using electrospray ionization were investigated. The analysis was performed using quadrupole time-of-flight mass spectrometry. Based on measurements carried out under various conditions, the way of fragmentation of the tested compounds that were divided into groups due to their chemical structure was established. The study showed that the bond between the carbon atom of the carbonyl group and the ring or NH group attached to the ring was mainly cleaved. This mechanism was adequate for the fragmentation of first-generation synthetic cannabinoids. This paper presents characteristic ions formed by synthetic cannabinoids (i.e., ions originating from an indole/indazole ring and an adamanyl/naphthalene/quinoline ring) using electrospray ionization. Knowledge of these specific fragments can be used in forensic laboratories to determine the structure of novel compounds from the group of synthetic cannabinoids. Graphical Abstract ᅟ.


Assuntos
Canabinoides/análise , Canabinoides/química , Drogas Desenhadas/análise , Drogas Desenhadas/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Íons/análise , Íons/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...